Dialysis following Transcatheter Aortic Valve Implantation: risk factors and outcomes: An analysis from the UK TAVI Registry

Mamas

Dialysis following Transcatheter Aortic Valve Implantation: risk factors and outcomes: An analysis from the UK TAVI Registry Thumbnail


Authors



Abstract

Objectives
This study sought to determine the risk factors for post-transcatheter aortic valve replacement (TAVR) dialysis and to determine the impact of pre-TAVR or post-TAVR dialysis on mortality.

Background
TAVR is now established as an alternative treatment to surgical aortic valve replacement. Data examining the impact of dialysis on outcomes after TAVR are lacking.

Methods
The UK TAVI (Transcatheter Aortic Valve Implantation) Registry was established to report outcomes on all TAVR procedures performed within the United Kingdom (2007 to 2014). Data were collected prospectively on 6,464 patients with a median follow-up of 625 days.

Results
The proportion of patients on dialysis before TAVR has remained constant at 1.8%. After TAVR, the proportion of patients newly needing dialysis after TAVR has fallen from 6.1% (2007 to 2008) to 2.3% (2013 to 2014). The risk of new dialysis requirement after TAVR was independently associated with lower baseline renal function, year of procedure, impaired left ventricular function, diabetes, use of an Edwards valve, a nontransfemoral approach, need for open surgery, and moderate-to-severe aortic regurgitation after the procedure. Requirement for new dialysis after TAVR was associated with higher mortality at 30 days (hazard ratio: 6.44; 95% confidence interval: 4.87 to 8.53) and at 4 years (hazard ratio: 3.54; 95% confidence interval: 2.99 to 4.19; p < 0.001 for all) compared with patients without dialysis requirement.

Conclusions
The proportion of patients needing dialysis after TAVR has decreased over time. Post-TAVR dialysis is associated with increased mortality. Factors identified with dialysis requirement after TAVR require further investigation.

Citation

Mamas. (2017). Dialysis following Transcatheter Aortic Valve Implantation: risk factors and outcomes: An analysis from the UK TAVI Registry. JACC. Cardiovascular interventions, 2040-2047. https://doi.org/10.1016/j.jcin.2017.05.020

Acceptance Date May 4, 2017
Publication Date Oct 23, 2017
Journal JACC: Cardiovascular Interventions
Print ISSN 1876-7605
Pages 2040-2047
DOI https://doi.org/10.1016/j.jcin.2017.05.020
Keywords mortality, acute kidney injury, valve type
Publisher URL https://doi.org/10.1016/j.jcin.2017.05.020