First clinical evidence characterizing safety and efficacy of the new CoCr Biolimus-A9 eluting stent: The Biomatrix Alpha™ registry
Mamas
Authors
Abstract
Background The biolimus-eluting stent (BES) was the first to elute anti-proliferative drug from a biodegradable polymer. In the randomized LEADERS trial, a stainless steel BES showed non-inferior efficacy compared to a sirolimus-eluting stent and a long-term safety advantage. We report the first clinical efficacy and safety outcomes of a new thin-strut cobalt chromium biolimus-eluting stent (CoCr-BES) from an international multi-centre registry. Methods We studied 400 all-comer patients with coronary disease receiving CoCr-BES at 12 centres, with follow-up at 9 months and 2 years. The primary endpoint was incidence of major adverse cardiac events (MACE) at 9 months comprising cardiac death, myocardial infarction (MI), and clinically indicated target vessel revascularization (ci-TVR). Key protocol elements were the same as the randomized LEADERS trial to enable a historical control for propensity-matched comparison. Results Mean patient age was 65 ± 11 years, 19% had diabetes, and 55% presented with unstable angina or MI. On discharge, 96% of patients were on dual antiplatelet therapy (DAPT) and 69% were on DAPT at 9 months. MACE at 9 months occurred in 3.9% of patients, cardiac death in 0.8%, MI in 1.1% and ci-TVR in 2.7%. One patient (0.25%) experienced definite or probable stent thrombosis (ST). A propensity-adjusted comparison showed similar clinical outcomes to the BES arm in the LEADERS trial for the primary endpoint MACE. Conclusions The new CoCr-BES showed low rates of MACE, MI, ci-TVR and ST at 9 months, similar to the BES arm in LEADERS.
Citation
Mamas. (2020). First clinical evidence characterizing safety and efficacy of the new CoCr Biolimus-A9 eluting stent: The Biomatrix Alpha™ registry. https://doi.org/10.1016/j.ijcha.2020.100472
Acceptance Date | Jan 14, 2020 |
---|---|
Publication Date | Jan 27, 2020 |
Journal | IJC Heart & Vasculature |
Print ISSN | 2352-9067 |
DOI | https://doi.org/10.1016/j.ijcha.2020.100472 |
Keywords | Drug eluting stent; Biodegradable polymer; Cobalt-chromium; Strut thickness; Myocardial infarction; Stent thrombosis |
Publisher URL | https://doi.org/10.1016/j.ijcha.2020.100472 |
Files
1-s2.0-S235290672030004X-main.pdf
(680 Kb)
PDF
Publisher Licence URL
https://creativecommons.org/licenses/by-nc-nd/4.0/
You might also like
Downloadable Citations
About Keele Repository
Administrator e-mail: research.openaccess@keele.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2024
Advanced Search