Skip to main content

Research Repository

Advanced Search

Phosphorus and sulfur metabonomic profiling of tissue and plasma obtained from tumour-bearing mice using ultra-performance liquid chromatography/inductively coupled plasma mass spectrometry: Profiling of tissue and plasma samples using UPLC/ICP-MS

Thompson, David F.; Michopoulos, Filippos; Smith, Christopher J.; Duckett, Catherine J.; Wilkinson, Robert W.; Jarvis, Philip; Wilson, Ian D.

Authors

Filippos Michopoulos

Christopher J. Smith

Catherine J. Duckett

Robert W. Wilkinson

Philip Jarvis

Ian D. Wilson



Abstract

RATIONALE
Metabonomic studies use complex biological samples (blood plasma/serum, tissues, etc.) that when analysed with high-performance liquid chromatography/mass spectrometry (HPLC/MS) or nuclear magnetic resonance (NMR) generate profiles that may contain many thousands of features. These profiles can be difficult to interpret with the majority of the features contributing little to the study. As such there is an argument for the development of techniques that can simplify the problem by targeting particular classes of compounds.

METHODS
In this study ultra-performance liquid chromatography/inductively coupled plasma mass spectrometry (UPLC/ICP-MS) was used to profile tumour tissue and plasma samples for phosphorus- and sulfur-containing metabolites. These samples were xenograft tumours (derived from breast, lung and colon cell lines) and plasma obtained from nude mice. Plasma was also obtained from non-tumour-bearing mice as a control. Due to isobaric interferences this method took advantage of the dynamic reaction cell within the ICP-MS system to react the phosphorus and sulfur ions with oxygen. The PO+ and SO+ ions were then monitored free of interferences. The total phosphorus and sulfur within each sample was also recorded using flow injection ICP-MS. A robust quality control system based on pooled sample replicate analysis was used throughout the study.

RESULTS
Determination of the total phosphorus and sulfur content of each sample was sufficient in itself for statistical differentiation between the majority of the cell lines analysed. Subsequent reversed-phase chromatographic profiling of the organic tumour and plasma extracts revealed the presence of a number of well-retained phosphorus-containing compounds that showed tumour-specific profiles. Reversed-phase profiling was not suitable for the sulfur-containing compounds which eluted with the solvent front.

CONCLUSIONS
This study has shown the potential use of UPLC/ICP-MS to differentiate between tumour cell lines, using both plasma and tumour tissue samples, based solely on metabolites that contain phosphorus or sulfur. Whilst further work is required to identify these compounds this methodology shows the ability of the described methods to provide targets for future biomarker discovery studies. Copyright © 2013 John Wiley & Sons, Ltd.

Citation

Thompson, D. F., Michopoulos, F., Smith, C. J., Duckett, C. J., Wilkinson, R. W., Jarvis, P., & Wilson, I. D. (2013). Phosphorus and sulfur metabonomic profiling of tissue and plasma obtained from tumour-bearing mice using ultra-performance liquid chromatography/inductively coupled plasma mass spectrometry: Profiling of tissue and plasma samples using UPLC/ICP-MS. Rapid Communications in Mass Spectrometry, 27(22), 2539-2545. https://doi.org/10.1002/rcm.6722

Journal Article Type Article
Acceptance Date Aug 24, 2013
Online Publication Date Oct 7, 2013
Publication Date Nov 30, 2013
Deposit Date Jun 16, 2023
Journal Rapid Communications in Mass Spectrometry
Print ISSN 0951-4198
Publisher Wiley
Peer Reviewed Peer Reviewed
Volume 27
Issue 22
Pages 2539-2545
DOI https://doi.org/10.1002/rcm.6722
Keywords Organic Chemistry; Spectroscopy; Analytical Chemistry