AIMS: To examine the utility of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) in the early diagnosis of cardiac implantable electronic device (CIED) generator pocket infection. METHODS AND RESULTS: A total of 86 patients with CIEDs were evaluated with (18)F-FDG PET/CT imaging: 46 with suspected generator pocket infection and 40 without any history of infection. (18)F-FDG activity in the region of the generator pocket was expressed as a semi-quantitative ratio (SQR)-defined as the maximum count rate around the CIED divided by the mean count rate between normal right and left lung parenchyma. All patients underwent standard clinical management, independent of the PET/CT result. Patients with suspected generator pocket infection that required CIED extraction (n = 32) had significantly higher (18)F-FDG activity compared with those that did not (n = 14), and compared with controls (n = 40) [SQR: 4.80 (3.18-7.05) vs. 1.40 (0.88-1.73) vs. 1.10 (0.98-1.40), respectively; P < 0.001]. On receiver operator characteristic analysis, SQR had a high diagnostic accuracy (area under curve = 0.98) for the early identification of patients with confirmed infection (i.e. those ultimately needing extraction)-with an optimal SQR cut-off value of >2.0 (sensitivity = 97%; specificity = 98%). CONCLUSION: This study highlights the potential benefits of evaluating patients with suspected CIED generator pocket infection using (18)F-FDG PET/CT. In this study, (18)F-FDG PET/CT had a high diagnostic accuracy in the early diagnosis of CIED generator pocket infection, even where initial clinical signs were underwhelming.

Citation

Mamas. (2015). Early diagnosis of cardiac implantable electronic device generator pocket infection using 18F-FDG-PET/CT. European Heart Journal - Cardiovascular Imaging, 521 - 530. https://doi.org/10.1093/ehjci/jeu295

Acceptance Date Feb 4, 2015
Publication Date May 1, 2015
Journal European Heart Journal - Cardiovascular Imaging
Print ISSN 2047-2404
Publisher Oxford University Press
Pages 521 - 530
DOI https://doi.org/10.1093/ehjci/jeu295
Keywords pacemakers, infection, generator pocket infection, imaging and diagnostics, nuclear cardiology, F-FDG PET/CT
Publisher URL http://ehjcimaging.oxfordjournals.org/content/16/5/521

Files






You might also like



Downloadable Citations